Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
No picture, Hole blown through LOPT. Had problems tracking down replacement – little tip given to me by Hantarex engineer – you can use the LOPT from an MTC9000 as long as you cut pin 2 off. (If you leave it connected, you will get a direct short to GND)
Carnival on a Gremlin / Sega Vic Dual PCB. Just had blue bars on screen, although probing the Z80 showed it was trying to run code. Using a logic probe I discovered that the /WRITE signal of the ram chips was always high. This signal comes from a 74LS10 at U77. Checked this chip and…
Altered Beast – Colours missing, no reds, other colours looked like diminished palette (like windows in 16 colours) – used test mode to perform ram test, and one ram chip identified as faulty (I10). Replaced this and red was back, but still reduced pallette. Looking at colour circuit, and it uses resistor arrays driven by I11…
The board originally failed to get into the game, instead resetting just after drawing the ‘MISSILE COMMAND’ logo. Test mode faired a little better, managing to report RAM OK, MAP OK and ROM OK before resetting. Ram and Rom checked out OK using the Fluke. Measuring various CPU signals revealed that the interrupt seemed very…
No Sound. Signal at output of SN76477 pin 13, follow through to input of sound amp, then from output until we reach electrolytic capacitor used to decouple connection to speaker. Signal going in, nothing coming out – replace capacitor sound back to normal. Only drawing a few pixels of player balloon sprite. Following the schematics,…
Screen filled with coloured lines, unstable, no sync (see above) – check clock signals from horizontal and vertical scan generators (74161’s at 2R,2S,3R,3S) – no signal feeding into pin 2 of horizontal generators. Follow trace back to 7474 at 3N, signal going in, nothing coming out – replace chip and screen display back to normal….