Lady Bug

Board ID 8016 : Falcon version ?

Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.

Similar Posts

  • Mr Do!

    Blank screen, Blanking line to output colour proms always enabled. Trace back to 74161 in timing circuit – output stuck, input clock all look OK – replace chip and picture appears. Blue video only – The video lines are controlled by three transistors near the edge connector, checking these revealed that 2 were not giving…

  • Frogger (Sega)

    Missing Chip. This was a converted moon cresta board. The IC at 1.2S (shoehorned in sideways between rows 1 and 2 by the sprite ram) was missing. This was not featured on any schematics I had, so I traced the connections to see what it could be. It basically takes the output from the sprite…

  • Namco Time Crisis 2 Gun

    One of the guns on a Time Crisis 2 was no longer registering shots on the screen. Following checks on wiring, cleaning lens, etc. it appeared that the optical sensor (opto) was dead. This is a small PCB in the gun, 2421961100, pictured above. I couldn’t find any schematics or information about the parts used,…

  • Galaxian

    No display – When move board, display flickers – go around board pushing each chip in turn, when press on 2E picture appears. Pin 16 rusted, only just in place. replace chip – picture back to normal. No star display. Board had been hacked to play an alternate game, pin 15 on chip 2B had…

  • Hantarex MTC9000/A

    No picture, Hole blown through LOPT. Had problems tracking down replacement – little tip given to me by Hantarex engineer – you can use the LOPT from an MTC9000 as long as you cut pin 2 off. (If you leave it connected, you will get a direct short to GND)

  • Pacman

    Screen filled with coloured lines, unstable, no sync (see above) – check clock signals from horizontal and vertical scan generators (74161’s at 2R,2S,3R,3S) – no signal feeding into pin 2 of horizontal generators. Follow trace back to 7474 at 3N, signal going in, nothing coming out – replace chip and screen display back to normal….