Lady Bug

Board ID 8016 : Falcon version ?

Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.

Similar Posts

  • Sega System 16

    Altered Beast – Colours missing, no reds, other colours looked like diminished palette (like windows in 16 colours) – used test mode to perform ram test, and one ram chip identified as faulty (I10). Replaced this and red was back, but still reduced pallette. Looking at colour circuit, and it uses resistor arrays driven by I11…

  • Carnival

    Carnival on a Gremlin / Sega Vic Dual PCB. Just had blue bars on screen, although probing the Z80 showed it was trying to run code. Using a logic probe I discovered that the /WRITE signal of the ram chips was always high. This signal comes from a 74LS10 at U77. Checked this chip and…

  • Missile Command

    The board originally failed to get into the game, instead resetting just after drawing the ‘MISSILE COMMAND’ logo. Test mode faired a little better, managing to report RAM OK, MAP OK and ROM OK before resetting. Ram and Rom checked out OK using the Fluke. Measuring various CPU signals revealed that the interrupt seemed very…

  • Hantarex MTC9000/A

    No picture, Hole blown through LOPT. Had problems tracking down replacement – little tip given to me by Hantarex engineer – you can use the LOPT from an MTC9000 as long as you cut pin 2 off. (If you leave it connected, you will get a direct short to GND)

  • Frogger (Sega)

    Missing Chip. This was a converted moon cresta board. The IC at 1.2S (shoehorned in sideways between rows 1 and 2 by the sprite ram) was missing. This was not featured on any schematics I had, so I traced the connections to see what it could be. It basically takes the output from the sprite…

  • Pacman

    Screen filled with coloured lines, unstable, no sync (see above) – check clock signals from horizontal and vertical scan generators (74161’s at 2R,2S,3R,3S) – no signal feeding into pin 2 of horizontal generators. Follow trace back to 7474 at 3N, signal going in, nothing coming out – replace chip and screen display back to normal….