Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
Crashing game. Game woud start attract mode, but shortly after would crash and boot loop. Entering test mode (hold player 1 start button whilst switching on) and it would pass first time around, but fail at random addresses on subsequent runs. The /WAIT signal on the main Z80 is handled by the IC at E2…
I had a spare bootleg replacement play pack from a Driving force on Galaxian hardware, so I proceeded to trace the circuit and try to identify the ICs used since they all have the IDs removed, other that the one attached as a later addition as IC7. Following the tracing, I used the pinouts to…
Ran through self test OK, came up with chequer board screen and then reset most of the time. Occasionally would start game, but with credit noise continually playing and credits rapidly counting upwards. This is caused by CPU 4 (E5) not running properly. checked the eprom and ram (C5,D5 and E5) and ram was faulty….
One of the guns on a Time Crisis 2 was no longer registering shots on the screen. Following checks on wiring, cleaning lens, etc. it appeared that the optical sensor (opto) was dead. This is a small PCB in the gun, 2421961100, pictured above. I couldn’t find any schematics or information about the parts used,…
Totally dead, no screen display (blank white screen). For this I used the Fluke Z80-S2650 adapter to check out the ram and rom, and located two errors. The rom mapping was incorrect, with a large range of locations returning random values. Examining the board (since I have no schematics), all of the chip select lines meet up…
Screen filled with coloured lines, unstable, no sync (see above) – check clock signals from horizontal and vertical scan generators (74161’s at 2R,2S,3R,3S) – no signal feeding into pin 2 of horizontal generators. Follow trace back to 7474 at 3N, signal going in, nothing coming out – replace chip and screen display back to normal….