Lady Bug

Board ID 8016 : Falcon version ?

Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.

Similar Posts

  • Dark Seal

    Glitched graphics. Screen changes as board is flexed. Moved around board pressing chips until pressing the custom surface mount chip at B6 changed the effect. Noticed that the corner most pins had come up from the board. After an unsuccessful effort to resolder them, I used some enameled 38 swg wire to solder from the…

  • Gorf

    Capacitor burnt. (game board), particularly at C37 the capacitor was showing signs of extreme heat. Replaced them all with 22uF 25V axial electrolytics. No Speech / Some SFX missing. (game board) Output from speech chip SC01 was OK, as was output from IO Custom (X3). checked transistors in output stage and 2N4401 was faulty. (Q2)…

  • Rainbow Island

    On power up – black screen, no sign of life at all. I removed the 68000 CPU and fitted a socket, so I could use the Fluke on it. This revealed that the main program ram ($10C000-$10FFFF) was totally dead. Replacing the two ram chips IC25 and IC26 solved this problem. Board now started up,…

  • Frogger (Sega)

    Missing Chip. This was a converted moon cresta board. The IC at 1.2S (shoehorned in sideways between rows 1 and 2 by the sprite ram) was missing. This was not featured on any schematics I had, so I traced the connections to see what it could be. It basically takes the output from the sprite…

  • Missile Command

    The board originally failed to get into the game, instead resetting just after drawing the ‘MISSILE COMMAND’ logo. Test mode faired a little better, managing to report RAM OK, MAP OK and ROM OK before resetting. Ram and Rom checked out OK using the Fluke. Measuring various CPU signals revealed that the interrupt seemed very…

  • Pacman

    Screen filled with coloured lines, unstable, no sync (see above) – check clock signals from horizontal and vertical scan generators (74161’s at 2R,2S,3R,3S) – no signal feeding into pin 2 of horizontal generators. Follow trace back to 7474 at 3N, signal going in, nothing coming out – replace chip and screen display back to normal….