Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
Boots up, and plays, but incorrect sprites – most noticeable little bug changes into ‘END’ at one point. Check 74ls138 at 8n, controlling graphics banking, and pins strobing. Replace chip and now uses correct sprites. Quiet missile sound and explosion sound. Both of these effects use the op-amp chip, LM324 at 7T. Replace this chip…
Crashing game. Game woud start attract mode, but shortly after would crash and boot loop. Entering test mode (hold player 1 start button whilst switching on) and it would pass first time around, but fail at random addresses on subsequent runs. The /WAIT signal on the main Z80 is handled by the IC at E2…
In normal mode, just had a blank screen. Enable test mode and you instead get an error message showing that the ROM test had failed (even though the rom itself checks out OK with correct content) This is because the custom Atari SLAPSTIC chip is not functioning correctly. It is used to page banks of…
The board originally failed to get into the game, instead resetting just after drawing the ‘MISSILE COMMAND’ logo. Test mode faired a little better, managing to report RAM OK, MAP OK and ROM OK before resetting. Ram and Rom checked out OK using the Fluke. Measuring various CPU signals revealed that the interrupt seemed very…
One of the guns on a Time Crisis 2 was no longer registering shots on the screen. Following checks on wiring, cleaning lens, etc. it appeared that the optical sensor (opto) was dead. This is a small PCB in the gun, 2421961100, pictured above. I couldn’t find any schematics or information about the parts used,…
Screen filled with coloured lines, unstable, no sync (see above) – check clock signals from horizontal and vertical scan generators (74161’s at 2R,2S,3R,3S) – no signal feeding into pin 2 of horizontal generators. Follow trace back to 7474 at 3N, signal going in, nothing coming out – replace chip and screen display back to normal….