Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
No Sound. Signal at output of SN76477 pin 13, follow through to input of sound amp, then from output until we reach electrolytic capacitor used to decouple connection to speaker. Signal going in, nothing coming out – replace capacitor sound back to normal. Only drawing a few pixels of player balloon sprite. Following the schematics,…
Missing Chip. This was a converted moon cresta board. The IC at 1.2S (shoehorned in sideways between rows 1 and 2 by the sprite ram) was missing. This was not featured on any schematics I had, so I traced the connections to see what it could be. It basically takes the output from the sprite…
On power up – black screen, no sign of life at all. I removed the 68000 CPU and fitted a socket, so I could use the Fluke on it. This revealed that the main program ram ($10C000-$10FFFF) was totally dead. Replacing the two ram chips IC25 and IC26 solved this problem. Board now started up,…
Boots up, and plays, but incorrect sprites – most noticeable little bug changes into ‘END’ at one point. Check 74ls138 at 8n, controlling graphics banking, and pins strobing. Replace chip and now uses correct sprites. Quiet missile sound and explosion sound. Both of these effects use the op-amp chip, LM324 at 7T. Replace this chip…
In normal mode, just had a blank screen. Enable test mode and you instead get an error message showing that the ROM test had failed (even though the rom itself checks out OK with correct content) This is because the custom Atari SLAPSTIC chip is not functioning correctly. It is used to page banks of…
Screen filled with coloured lines, unstable, no sync (see above) – check clock signals from horizontal and vertical scan generators (74161’s at 2R,2S,3R,3S) – no signal feeding into pin 2 of horizontal generators. Follow trace back to 7474 at 3N, signal going in, nothing coming out – replace chip and screen display back to normal….