Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
Blank screen, Blanking line to output colour proms always enabled. Trace back to 74161 in timing circuit – output stuck, input clock all look OK – replace chip and picture appears. Blue video only – The video lines are controlled by three transistors near the edge connector, checking these revealed that 2 were not giving…
Screen filled with coloured lines, unstable, no sync (see above) – check clock signals from horizontal and vertical scan generators (74161’s at 2R,2S,3R,3S) – no signal feeding into pin 2 of horizontal generators. Follow trace back to 7474 at 3N, signal going in, nothing coming out – replace chip and screen display back to normal….
Glitched graphics. Screen changes as board is flexed. Moved around board pressing chips until pressing the custom surface mount chip at B6 changed the effect. Noticed that the corner most pins had come up from the board. After an unsuccessful effort to resolder them, I used some enameled 38 swg wire to solder from the…
I had a spare bootleg replacement play pack from a Driving force on Galaxian hardware, so I proceeded to trace the circuit and try to identify the ICs used since they all have the IDs removed, other that the one attached as a later addition as IC7. Following the tracing, I used the pinouts to…
No Sound. Signal at output of SN76477 pin 13, follow through to input of sound amp, then from output until we reach electrolytic capacitor used to decouple connection to speaker. Signal going in, nothing coming out – replace capacitor sound back to normal. Only drawing a few pixels of player balloon sprite. Following the schematics,…
Totally dead, no screen display (blank white screen). For this I used the Fluke Z80-S2650 adapter to check out the ram and rom, and located two errors. The rom mapping was incorrect, with a large range of locations returning random values. Examining the board (since I have no schematics), all of the chip select lines meet up…