Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
Board ID 8016 : Falcon version ?
Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.
6 Slot – Memory test on power up giving error Address Write Read 00008000 5555 55FF Checking with Mame, the memory chips in question were only small, so looking at the board revealed two DIL 5814’s. Chip select signals to these were toggling as expected, so I needed to identify which ram chip was which….
Ran through self test OK, came up with chequer board screen and then reset most of the time. Occasionally would start game, but with credit noise continually playing and credits rapidly counting upwards. This is caused by CPU 4 (E5) not running properly. checked the eprom and ram (C5,D5 and E5) and ram was faulty….
Boots up, and plays, but incorrect sprites – most noticeable little bug changes into ‘END’ at one point. Check 74ls138 at 8n, controlling graphics banking, and pins strobing. Replace chip and now uses correct sprites. Quiet missile sound and explosion sound. Both of these effects use the op-amp chip, LM324 at 7T. Replace this chip…
I had a spare bootleg replacement play pack from a Driving force on Galaxian hardware, so I proceeded to trace the circuit and try to identify the ICs used since they all have the IDs removed, other that the one attached as a later addition as IC7. Following the tracing, I used the pinouts to…
Boot up with garbage, quickly clears screen and then nothing. Used Fluke with Z80 pod – read rom OK, and write ram OK, but timeout reading any Ram location. Check fluke status and ‘wait’ always set. Check pin 24 of Z80– stuck low, trace back through 7H,7C,6C1 to 6B1 pin 2 – always low, although…
No picture, Hole blown through LOPT. Had problems tracking down replacement – little tip given to me by Hantarex engineer – you can use the LOPT from an MTC9000 as long as you cut pin 2 off. (If you leave it connected, you will get a direct short to GND)