Lady Bug

Board ID 8016 : Falcon version ?

Static graphics on screen, dead – pin 24 low on Z80, /WAIT signal. Trace signal on board to 74LS74 at E7. Signal incorrect for inputs. Replace with new one, board fixed.

Similar Posts

  • Moon Cresta

    Boots up, and plays, but incorrect sprites – most noticeable little bug changes into ‘END’ at one point. Check 74ls138 at 8n, controlling graphics banking, and pins strobing. Replace chip and now uses correct sprites. Quiet missile sound and explosion sound. Both of these effects use the op-amp chip, LM324 at 7T. Replace this chip…

  • Namco Time Crisis 2 Gun

    One of the guns on a Time Crisis 2 was no longer registering shots on the screen. Following checks on wiring, cleaning lens, etc. it appeared that the optical sensor (opto) was dead. This is a small PCB in the gun, 2421961100, pictured above. I couldn’t find any schematics or information about the parts used,…

  • Atari Tetris

    In normal mode, just had a blank screen. Enable test mode and you instead get an error message showing that the ROM test had failed (even though the rom itself checks out OK with correct content) This is because the custom Atari SLAPSTIC chip is not functioning correctly. It is used to page banks of…

  • Carnival

    Carnival on a Gremlin / Sega Vic Dual PCB. Just had blue bars on screen, although probing the Z80 showed it was trying to run code. Using a logic probe I discovered that the /WRITE signal of the ram chips was always high. This signal comes from a 74LS10 at U77. Checked this chip and…

  • Make Trax

    Boot up with garbage, quickly clears screen and then nothing. Used Fluke with Z80 pod – read rom OK, and write ram OK, but timeout reading any Ram location. Check fluke status and ‘wait’ always set. Check pin 24 of Z80– stuck low, trace back through 7H,7C,6C1 to 6B1 pin 2 – always low, although…

  • Pacman

    Screen filled with coloured lines, unstable, no sync (see above) – check clock signals from horizontal and vertical scan generators (74161’s at 2R,2S,3R,3S) – no signal feeding into pin 2 of horizontal generators. Follow trace back to 7474 at 3N, signal going in, nothing coming out – replace chip and screen display back to normal….