No picture, Hole blown through LOPT. Had problems tracking down replacement – little tip given to me by Hantarex engineer – you can use the LOPT from an MTC9000 as long as you cut pin 2 off. (If you leave it connected, you will get a direct short to GND)
Similar Posts
Moon Cresta
ByadminBoots up, and plays, but incorrect sprites – most noticeable little bug changes into ‘END’ at one point. Check 74ls138 at 8n, controlling graphics banking, and pins strobing. Replace chip and now uses correct sprites. Quiet missile sound and explosion sound. Both of these effects use the op-amp chip, LM324 at 7T. Replace this chip…
Century Play Pack (Driving Force)
ByadminI had a spare bootleg replacement play pack from a Driving force on Galaxian hardware, so I proceeded to trace the circuit and try to identify the ICs used since they all have the IDs removed, other that the one attached as a later addition as IC7. Following the tracing, I used the pinouts to…
Frogger (Sega)
Missing Chip. This was a converted moon cresta board. The IC at 1.2S (shoehorned in sideways between rows 1 and 2 by the sprite ram) was missing. This was not featured on any schematics I had, so I traced the connections to see what it could be. It basically takes the output from the sprite…
Galaxian
No display – When move board, display flickers – go around board pushing each chip in turn, when press on 2E picture appears. Pin 16 rusted, only just in place. replace chip – picture back to normal. No star display. Board had been hacked to play an alternate game, pin 15 on chip 2B had…
Make Trax
ByadminBoot up with garbage, quickly clears screen and then nothing. Used Fluke with Z80 pod – read rom OK, and write ram OK, but timeout reading any Ram location. Check fluke status and ‘wait’ always set. Check pin 24 of Z80– stuck low, trace back through 7H,7C,6C1 to 6B1 pin 2 – always low, although…
Pacman
ByadminScreen filled with coloured lines, unstable, no sync (see above) – check clock signals from horizontal and vertical scan generators (74161’s at 2R,2S,3R,3S) – no signal feeding into pin 2 of horizontal generators. Follow trace back to 7474 at 3N, signal going in, nothing coming out – replace chip and screen display back to normal….