No picture, Hole blown through LOPT. Had problems tracking down replacement – little tip given to me by Hantarex engineer – you can use the LOPT from an MTC9000 as long as you cut pin 2 off. (If you leave it connected, you will get a direct short to GND)
Similar Posts
Dark Seal
Glitched graphics. Screen changes as board is flexed. Moved around board pressing chips until pressing the custom surface mount chip at B6 changed the effect. Noticed that the corner most pins had come up from the board. After an unsuccessful effort to resolder them, I used some enameled 38 swg wire to solder from the…
Rainbow Island
ByadminOn power up – black screen, no sign of life at all. I removed the 68000 CPU and fitted a socket, so I could use the Fluke on it. This revealed that the main program ram ($10C000-$10FFFF) was totally dead. Replacing the two ram chips IC25 and IC26 solved this problem. Board now started up,…
Moon Cresta
ByadminBoots up, and plays, but incorrect sprites – most noticeable little bug changes into ‘END’ at one point. Check 74ls138 at 8n, controlling graphics banking, and pins strobing. Replace chip and now uses correct sprites. Quiet missile sound and explosion sound. Both of these effects use the op-amp chip, LM324 at 7T. Replace this chip…
Frogger (Sega)
Missing Chip. This was a converted moon cresta board. The IC at 1.2S (shoehorned in sideways between rows 1 and 2 by the sprite ram) was missing. This was not featured on any schematics I had, so I traced the connections to see what it could be. It basically takes the output from the sprite…
Galaxian
No display – When move board, display flickers – go around board pushing each chip in turn, when press on 2E picture appears. Pin 16 rusted, only just in place. replace chip – picture back to normal. No star display. Board had been hacked to play an alternate game, pin 15 on chip 2B had…
Pacman
ByadminScreen filled with coloured lines, unstable, no sync (see above) – check clock signals from horizontal and vertical scan generators (74161’s at 2R,2S,3R,3S) – no signal feeding into pin 2 of horizontal generators. Follow trace back to 7474 at 3N, signal going in, nothing coming out – replace chip and screen display back to normal….